Elliptical flowmeter
A high-precision positive-displacement flowmeter suitable for a wide range of fluids, including water, petroleum products, and solvents. Featuring a mechanical counter, it allows on-site verification of cumulative flow. Additionally, an output option is available.
Characteristic
Specialty
- High accuracy: ±0.5% RD (optional: ±0.2% RD)
- The metering chamber has virtually no dead volume, making it suitable for a wide range of liquids, including chemical fluids.
- Low pressure loss, high durability
Main Specifications
| Aircraft model | Integrated inner and outer cylinders | Separate inner and outer cylinder design | |||
| Nominal diameter | 80–200mm | 250–300 mm | 25mm | 40, 50 mm | 50–200 mm |
| Transmission method | 7 | 4 | 2 | 4 | |
| Connection Specifications | JIS 10,20K | JIS 10,16,20,30K | JIS 30K | JIS 10,16,20,30,40,63K | |
| (Frank) | ASME/JPI 150 | ASME/JPI 150,300 | ASME 300 | ASME/JPI 150,300,600 | |
| Flow range ※ | 4–450 m 3/h (5 models) |
30–1000 m 3/h (2 models) |
0.08–4 m 3/h (2 models) |
0.26–40 m 3/h (3 models) |
2–450 m 3/h (6 models) |
| Operating temperature range | −10 to +120°C | −5 to +120°C | −5 to +120°C or +120 to +200°C | −5 to +120°C | |
| Maximum operating pressure | 1.96MPa (According to the connection specifications) |
4.59MPa (According to the connection specifications) |
4.51MPa (Below 120℃) |
9.51MPa (According to the connection specifications) |
|
| Accuracy | Within ±0.5% or ±0.2% of the indicated value | ||||
| Power supply | Do not (include output; power supply required) | ||||
| Output | Pulse (Selection) | ||||
| Structure | Can support explosion-proof devices with output. | ||||
| Applicable fluid | Water, gasoline, light oil, heavy oil, etc. | ||||
※When the viscosity is 5 mPa·s or greater but less than 1000 mPa·s
Main specifications (with jacket)
| Aircraft model | Integrated inner and outer cylinders | |
| Nominal diameter | 25, 40, 50 mm | 100, 150, 200 mm |
| Transmission method | 7 | |
| Connection Specification (Flange) | JIS 10K, ASME 150 | |
| Flow range ※ | 0.15–38 m 3/h (5 forms) |
30–1000 m 3/h (2 forms) |
| Operating temperature range | -5 to +120°C or +120 to +200°C | |
| Maximum operating pressure | 1.18 MPa (below 220°C) | |
| Accuracy | Within ±0.5% of the displayed value | |
| Power supply | Do not (include output; power supply required) | |
| Output | Pulse (Selection) | |
| Structure | Can support explosion-proof devices with output. | |
| Applicable fluid | Water, gasoline, light oil, heavy oil, etc. | |
RELATED PRODUCTS
Inquiry
Jasmine (Suzhou) Co., Ltd., specializing in imported industrial automation and fluid components, focuses on genuine motors, drives, PLCs, sensors, pneumatic parts and spray systems. As an official agent of Spraying System and Aventics, we provide one-stop product supply, technical consultation and customized matching solutions for industrial and high-end equipment applications.