SMC9021

Flue gas emission continuous monitoring system
SMC9021

Characteristic

skim through

Benefits

Rapid condensate dewatering technology for smaller SO2 losses

Automatic drainage to liquid storage tanks reduces environmental contamination

Membrane filters to protect the analyzer's gas chamber

Accepts a wide range of transmitter signals

Data can be processed in conjunction with the specialized SMC900 data processing system.

Thermal insulation of the pipeline, no condensation during transportation of the sample gas.

Characteristics

Heated sampling probe, no cooling of the flue gas during the sampling process

Sampling probe with blowback function, extend the maintenance cycle

PLC control of automatic blowback, automatic drainage, automatic calibration, to ensure long-term work.

Alarm settings for temperature, flow rate and humidity can be provided to facilitate the operation of the inspection system.

Various configurations available (S700 series)

Additional auxiliary parameters can be added to the measurement (oxygen content, dust content, flow measurement, etc.)

Technical Details

measured value CO, CO2, NOx, O2, SO2
Tested and qualified measurements CO、CO2、NOx、O2、SO2
Measuring principle NDIR Spectroscopy, Electrochemical Cells
measurement segment 10 l/min ... 60 l/min
sample size ≤ 300 l/h8.48 m

Measurement range

co

NO

O2

SO2

0 ... 500 mg/m3 / 0 ... 2,500 mg/m3

0 ... 500 mg/m3 / 0 ... 2,500 mg/m3

0 ... 21 Vol .- %

0 ... 500 mg/m3 / 0 ... 2,500 mg/m3

Certified Measurement Range

CO

NO

SO2

0 ... 2,500 mg/m3

0 ... 2,500 mg/m3

0 ... 2,500 mg/m3

Response time (t90) ≤ 15 s
accuracy ≤ ± 1 %
Full scale value
(level of) sensitivity ≤ ± 1 %: end of weekly measuring range
zero drift ≤ ± 1 %: end of weekly measuring range
range drift   ≤ ± 1 %: end of weekly measuring range
detection limit     ≤ 1 %
resolution     ≤ 1 %
Process temperature ≤ +300 °C
Process pressure -100 hPa ... 100 hPa
relatively
Ambient temperature     +5 °C ... +35 °C
Storage temperature range     -20 °C ... +70 °C
Environmental stress     900 hPa ... 1,100 hPa
Ingress protection IP40
Analog output 4 Outputs.
4 ... 20 mA
Analog inputs 2 inputs can be selected
Switching output Selectable 4 outputs
Digital inputs 4 inputs can be selected
Dimensions (W x H x D) 800 mm x 2,100 mm x 800 mm
weight ≤ 300 kg

power supply

voltage

frequency

power consumption

220 V AC

50 Hz

≤ 2,000 VA

annex

Gauge air supply: ≥ 4 bar

≤ 100 l/min
When blowing back

Sample gas connection

Sample gas inlet

Exhaust vents

8 mm diameter

14 mm diameter

Assist gas connection

Instrument air supply

DN 6/8
Correction function Manual or automatic calibration by standard gas
System components

Gas sampling unit

Sample gas pipes

Analysis cabinet

Connecting units

Integrated components

Temperature sensor

Pressure sensors

Humidity sensor

Flow sensors

SMC900

 

RELATED PRODUCTS

Nozzle

SpiralJet

View More

Nozzle

Fulljet Maximum Free Passage (MFP)

View More

Nozzle

QPHA Spray Tip + QPPA Body

View More

Nozzle

FullJet H Nozzles

View More

Nozzle

WashJet ® Nozzles

View More

Nozzle

Quick VeeJet® and ProMax® Quick VeeJet Nozzles

View More

Inquiry

Jasmine (Suzhou) Co., Ltd., specializing in imported industrial automation and fluid components, focuses on genuine motors, drives, PLCs, sensors, pneumatic parts and spray systems. As an official agent of Spraying System and Aventics, we provide one-stop product supply, technical consultation and customized matching solutions for industrial and high-end equipment applications.